❄️ Why Do I See Ice on My Aircon Pipes?
- bryan chia

- Nov 19, 2025
- 2 min read
Seeing ice forming on your aircon pipes may look harmless, but it’s actually a sign that something isn’t working properly inside your system. Aircon pipes should never freeze under normal operation. When they do, it means airflow, refrigerant levels, or internal components are struggling to function the way they should.
If left unchecked, frozen pipes can lead to water leaks, weak cooling, and even compressor damage. Here’s why it happens.

1. Restricted Airflow
Your aircon needs warm air from the room to pass over its cooling coil. When airflow is blocked, the coil becomes too cold and starts freezing.
Common causes:
Dirty air filters
Dust-clogged coils
Blocked return vents
Solution: Clean filters every 2–3 weeks and schedule servicing to clear dust from the coil and blower fan.
2. Low Refrigerant (Gas) Levels
Refrigerant absorbs heat. If levels are low because of a leak, the coil temperature drops too fast, causing condensation to freeze around the copper pipes.
Signs:
Weak cooling
Hissing noise
Ice forming on copper tubes or coils
Solution: A technician must check for leaks and perform a proper gas top-up. Avoid topping up without leak testing, as it will freeze again.
3. Malfunctioning Blower Fan
If the blower fan is weak or faulty, the air won’t circulate properly. With insufficient warm air passing through, the coil temperature falls below freezing.
Solution: Have the fan motor and blower wheel checked, cleaned, or replaced if worn.
4. Frozen Evaporator Coil
Sometimes the coil is already partially frozen inside the unit. This spreads outward to the pipes as the system continues running.
Common causes:
Dirty coils
Blocked drainage
Long hours of use at very low temperature
Solution: Switch off the aircon to defrost. A chemical wash may be needed to fully clear the dirt buildup.
5. Running the Aircon at Very Low Temperatures
Setting your aircon to 16°C or 18°C for long hours can overwork the system and drop coil temperature too quickly.
Solution: Use 24°C to 26°C for normal usage. This reduces freezing issues and saves electricity.
How Sky Blue Aircon Can Help
At Sky Blue Aircon Engineering Pte Ltd, we fix freezing issues by checking the root cause rather than just clearing the ice.
Our Services Include:
Coil and blower cleaning
Gas leak detection and top-up
Fan motor repair
Drainage clearing and coil defrost
Chemical wash for deep cleaning
The Bottom Line
Ice on your aircon pipes is a warning sign — not something you should ignore. Proper servicing and early checks prevent bigger problems like water leaks, weak cooling, and compressor damage.